Arrhenius/FIT Rate Calculator

FIT with a single group
 
Confidence
 %
Total Tested
Hours Tested
Dev Hrs
Fails
Use Temp (°C)
Test Temp (°C)
Ea (eV)
kT1 (eV)
kT2 (eV)
A accel factor
Dev Hrs * A
FIT Rate
   

     
    FIT with a combination of two groups tested at different temperatures
     
    Group 1 Total Tested
    Hours Tested
    Dev Hrs
    Fails
    Use Temp (°C)
    Test Temp (°C)
    Ea (eV)
    at Tuse
    kT1 (eV)
    at Ttest
    kT2 (eV)
    A accel factor
    Dev Hrs * A
       
    Group 2
    Group 2
    2nd TP
    Combined Totals Total dev hrs * A factor =
            Total Fails
    Confidence
     %
      Combined
    FIT Rate
               
     
       

       

      Confidence: Enter as a whole number. E.g., for 90%, enter 90. Total Tested: Enter the total number of parts tested.
      Hours Tested: Enter the number of hours tested. Dev Hrs: This is a calculated field.
      Fails: Enter the total number of failures. Use Temp (°C): Enter the usage temperature.
      Test Temp (°C): Enter the test temperature. Ea (eV): Enter the Ea information.
      kT1 (eV): This is a calculated field. kT2 (eV): This is a calculated field.
      A accel factor: This is a calculated field. Dev Hrs * A: This is a calculated field.
      FIT Rate: This is a calculated field. Calculate: Totals the calculations when pressed.